CX5003 Dual NMEA2000 Converter Features:
- Acquisition of sensor parameters and convert to NME A2000 parameters
- Up to 18 sensors can be collected
Sensor Parameter:
- Speed ratio adjustable range is 1~200
- Engine tilt/trim 0~ 1 90ohm
- Oil pressure 10~184ohm(0~10bar)
- Temperature 301~22ohm(40~ 120`C)
- Rudder 0~1 90ohm
- Fuel level 0~ 190ohm
- Freshwater level 0~1 90ohm
- Wastewater level 0~ 1 90ohm
Environmental
- Operating Voltage 9 to 32 Volts(DC)
- Power Consumption <120mA
- Operating Temperature -30~75degrees
- Storage Temperature -40~ 85degrees
- Degree of Protection Ip67
Connection
1 , Connect to``Micro-C`` NMEA 2000 interface .
2 , Connect the corresponding interface
- according to the functional requirements
Single NMEA2000 Converter Features:
1. Acquisition of sensor parameters and convert to NMEA2000 parameters
2. Up to 13 sensors can be collected
Sensor Parameter:
Speed ratio adjustable range is 1~200
Engine tlt/trim 0~190ohm/240-33ohm
Oil pressure 10~184ohm(0~10bar)
Tepmerature 301~22ohm(40~120¡É)
Rudder 0~190ohm/240-33ohm
Fuel level 0~190ohm/240-33ohm
Freshwater level 0~190ohm/240-33ohm
Wastewater level 0~190ohm/240-33ohm
Environmental
Operating Voltage: 9 to 32 Volts(DC)
Power Consumption: <120mA
Operating Temperature: -30~75degrees
Storage Temperature: -40~85degrees
Degree of Protection: IP67
Connection
1. Connect to "Micro-C" NMEA2000 interface
2. Connect the corresponding interface according to the functional requirements
CX5005 Connector
Application :
For CX5003 NMEA 2000 Multifunction Converter
NMEA 2000 (N2k) (Tee) T-Connector
Description
Garmin NMEA2000 T-connectors
used for NMEA2000 network
OEM product
working well
Package:
1x NMEA2000 T-Connector
NMEA2000 Terminator
Description:
The Terminator, a M12 connector molded with a 120 ohm resistor inside it, located at each end of the NMEA 2000 backbone or other devices cable termination. Proper termination helps ensure signal integrity across the entire length of the boat backbone.
Applications:
~Serves to prevent the transmission into the network of the reflected signal.
~It is installed on all ends of free cables.
~If you need to expand the system in the future, the Terminator turns off, instead, the extension cord and additional T-connectors are connected. ~At the end of each trunk cable, we install the Terminator again.
~The resistor connector has a waterproof performance.
~Attached to each end of the trunk (backbone) cable to reduce reflections of the communication signals on the network.
~Proper termination helps ensure signal integrity across the entire length of the boat backbone.
Package Include:
1pcs X NMEA2000 Terminator
(Male #010-11080-00 5 Pin)
OR 1pcs X NMEA2000 Terminator
( Female #010-11081-00 5 Pin)
OR 1set X NMEA2000 Terminator