Applications
Install the Gauge
a. Cut an 85mm (3 3/8'') hole in the panel (II) allow a clearance of . behind the panel.
b. Remove fastening ring (I), insert gauge from front.
Tighten gauge (III) using fastening ring (I)
c. Connect the cables following the guide above
Parameter Setting"OILP" , "HOUR", "UNIT","PULSE","OIL","ATER"
Press & Hold the Button on back, then power on, LCD will switch show OILP, HOUR,UNIT,PULSE,OIL,ATER.
Release the button ,then menu will can be configured.
1." OILP"Oil Pressure
LCD will show "S 00000"ohm range 10-184¥Ø, press button to set target range depends on the Table A, then release button, and wait for menu to complete flashing.
Table A
Menu Serial | Ohm Signal Range | BAR | PSI |
S 00000 | 10-184¥Ø | 0-5bar | 0-72.5PSI |
S 00001 | 10-184¥Ø | 0-10bar | 0-145PSI |
S 00002 | 240-33¥Ø | 0-5bar | 0-72.5PSI |
S 00003 | 240-33¥Ø | 0-10bar | 0-145PSI |
2. " HOUR"Change Working Hours, unit: hour
LCD will show" 00000.0"0 hours. Press menu to set target value and wait for menu to complete flashing. Range 0~99999.9.
3." UNIT"Water Temperature: /Oil PressurePSI/BAR
LCD will switch show PSIbar. Press button to choose target unit, release
button and wait for menu to complete flashing
4. "PULSE"(Tach RPM Ratio, unit: 0.01 pulse/round. Eg, 100 indicates 1 pulse/round)
LCD will show"P2000"means 20pulses/round.Press button to change from 0 to 39999.
Release button and wait for menu to complete flashing
5. "OIL"(Set Fuel Gauge Signal)
LCD will show"o00002"ohm range 10~180¥Ø.Press button to set target ohm range depends on Table B
Release button and wait for menu to complete flashing.
Table B
o 00000 | 0-190¥Ø |
o 00001 | 0-180¥Ø |
o 00002 | 10-180¥Ø |
o 00003 | 240-33¥Ø |
o 00004 | 240-30¥Ø |
6. "ATER"(Set Water Temperature Signal)
LCD will show"t 00000"ohm range 291.4~22.4¥Ø.Press button to set target ohm range depends on Table C
Release button and wait for menu to complete flashing.
Table C
Menu Serial | Ohm Range | Temperature Range |
t 00000 | 291.4~22.4¥Ø | 40~120 | 104~248 |
t 00001 | 301~23¥Ø | 40~120 | 104~248 |
Please noted: After setting, you should disconnect both Power+ and GND, and then reconnect the two cables, then it will save the setting. If you just cut Power +, then it'll not work properly.