1,Introduction instrument
NC DKP6008 DC-DC step-down buck module module is a fully programmable digital display, small size, high power, high efficiency, stable. The use of advanced microprocessor controlled, precise voltage and current adjustment using the keys, can constant voltage constant current output, to facilitate secondary development and microcontroller or computer communications through port reserved. With four eight LED digital control, real-time display the output voltage and current. Meanwhile, the step-down module with CNC job status indicator, you can view real-time job status. The machine has an automatic output after power function can be turned on or off as needed, in addition to the machine also has a key lock function, you can lock the keys to adjust parameters to prevent misuse regulated output voltage and current parameters.
2, the instrument characteristics
1, the use of advanced microprocessors, the key can be precisely regulated output voltage and current;
2, 4 high brightness LED, can display the output voltage, current, capacity, time;
3, can be set to automatically output after power;
4, lockable parameter adjustment keys to prevent misuse adjustment disorder output voltage and current parameters.
5, can be reserved through the port with the MCU or computer communications, ease of secondary development
6, high-quality power devices with peripherals precision operational amplifier CV and CC loop configuration, which greatly improves the performance of the module;
7, using two 0.8mm double-wound high current inductor, input using two 470uF / 100V electrolytic capacitor, output using two 1000uF / 63V electrolytic capacitor, comes with fan cooling, the temperature rise is small, the output voltage quality is very good ;
8, all-digital display, easy to use;
9, can be constant voltage, constant current output;
10, working status indicator module with, respectively, the output OUT, constant voltage CV, constant current CC indicator, you can view real-time job status;
3, technical indicators
Input voltage range of | 6V¢¦65V |
Output voltage adjustment range | 0¢¦60V |
Output current range | 0¢¦8A |
Output power | 0¢¦400W |
Output*voltage*setting*resolution | 10mV |
Output current setting resolution | 10mA |
Power Effect | CV<0.5%+10mV CC<1%+10mA |
Load Effect | CV<0.5%+10mV CC<1%+10mA |
Output ripple | <40mVpp(Input 54V, output 12V, current 5A) |
100Hz volatility transmission ratio | < 1/10000 |
Typical efficiency | 88%(Input 54V, output 36V, current 3A) |
Voltage and current display precision | 10mV,10mA |
Voltage display error | ¡¾1%+20mV |
Current display error | ¡¾2%+20mA |
Response time | < 50ms |
Storage operations | M0 ~ M9 10 group stores |
Cooling | onboard radiator, please pay attention to ventilation |
Operating ambient temperature | 0¢¦40¡É |
Storage temperature | -20¢¦70¡É |
Environment | designed for indoor use with a maximum humidity of 80% |
Dimensions(length*width*height) | 135¡¿95¡¿38(mm) |
Module shown in Figure 2-1 DKP6008
Grade | Explanation | Grade | Explanation |
1 | cooling fan | 5 | digital Tube |
2 | the negative input terminal | 6 | operation indicator |
3 | enter the correct pole | 7 | output + |
4 | operation buttons | 8 | output - |
, the display shows
Digital display | Description |
00.00 | voltage value,00.00~60.00V |
0.00A | current values,0.00A~7.99A |
0.00C | capacity value,0.00AH~99.9AH |
0.00H | time value,0.00H~9.59H |
1,wiring
Correctly connect the input and output to ensure that the range of input voltage requirements, the reverse is prohibited.
2, set the voltage and current values
After the power-on default display format is the voltage set value, the voltage value displayed is "00.00", the unit is "V", for example, "12.00" means "12.00V". Press the "SET" button to switch to the current set value, the current value of the display format is "0.00A", the unit is "A", such as "1.20A" indicates "01.20A".
Setting method: Press the button to increase the value, press the button to decrease the set value, press accurately set, press can be quickly set. Press the "SET" button to switch to set the current or voltage value.
3, open output
After setting voltage and current values, you can directly press "OK" key to output, output after press "OK button" to switch voltage and current display.
4, adjust the output voltage and current values under the state
Output state when the voltage value is displayed by pressing the button on the output voltage can be increased by pressing the button under the output voltage can be reduced by pressing the button you can increase the current set value when displaying the current value, press the next button can reduce the current setting, press accurately set, press can be quickly set.
5, turn off the output
Output state, press the "SET" button to turn off the output.
6, the automatic power-output function
Automatic power-output function is enabled:
Press "SET" button to enter the parameter setting page, click on the button to adjust to "-F2-" option, then click on the "OK" button, digital display "Yo-0", click on the button, the display switches to "Yo -1 ", and finally click" OK "button to save the settings.
Auto power-output function close method:
Press "SET" button to enter the parameter setting page, click on the button to adjust to "-F2-" option, then click on the "OK" button, digital display "Yo-1", click on the next button, the display switches to "Yo -0 "and finally click" OK "button to save the settings.
7, function display output capacity
Under the current status display, press the "OK" button for 3 seconds to display x.xxC; capacitance value at that time is displayed, press "OK" button to restore the current display.
In the display voltage state, long press the "OK" button to display x.xxH more
than 3 seconds; the value of the time value is displayed, press "OK" button to restore the voltage display.
8, parameters save, recall
Save parameters:
Press "SET" button to enter the parameter setting page, click on the button or down button to adjust the "-F0-" option, then click on the "OK" button, digital display "Sn-0", click on the button or down button to change the address, and finally click "OK" button to save a good set parameters are saved to the corresponding address bits.
Parameters recall:
Press "SET" button to enter the parameter setting page, click on the button or down button to adjust the "-F1-" option, then click on the "OK" button, digital display "Lo-0", click on the button or down button to change the address, and finally click "OK" button to save parameters corresponding address bit out of tune.
A total of 0-9 ten-bit address, the default boot address bits 0 output data.
9, parameter adjustment key lock and unlock function
Lock keys Features:
After the lock button can lock function is turned "on" button and the "down" button, then you can not adjust the output voltage and current parameters. Adjust output parameters to prevent misuse of chaos, but "SET" and "OK" button and then you can use any.
Open the keyboard lock function method:
Output in the closed state, click on the "SET" key to display the setting parameters as voltage, press "OK" button, when "-LoC" Release the button when the digital display, this time it will be the parameter adjustment keys locked.
Off the key lock function method:
Output in the closed state, click on the "SET" key to display the current parameter setting, press "OK" button, release the button when the digital display "ULoC", the parameters will be adjusted at this time unlocking key.
Package include :
1pcs power supply modue