1¡¢Product selection model
XKC-C382-1P, (with 1 sensor);
XKC-C382-2P, (with 2 sensors);
XKC-C382-3P, (with 3 sensors); Overflow protection or Ingress protection
2¡¢Overview
XKC-C382-110V-220V-XP high and low level controller and two non-contact liquid level detection heads realize the function of liquid level high and low control: when the container liquid level is too low, the low liquid level alarm signal sent by the low liquid level sensor is triggered to trigger C382 The controller closes the relay and starts the water pump to add the liquid level. When the liquid level reaches a certain height, the high liquid level sensor sends out a signal to trigger the C382 controller to open the relay and automatically stop the water pump to work in this way. Thereby, the function of automatic control of the container liquid level is realized, and the container liquid level is kept stable.
3¡¢Product Features
AC110V-220V wide voltage power supply
Relay active contact output, suitable for various load control.
The control is diversified, and the pump can be controlled in manual or automatic mode.
Screw wall mounting is simple and convenient.
4¡¢Technical Parameters
1.Input voltage£ºAC 110V-220V (wide voltage)
2.The output voltage£ºAC 110V-220V
3.Working current£º¡Â7A
4.Operating Voltage£ºAC 110V-220V
5.Power consumption£º¡Â2W
6.Load power£ºWhen the supply voltage is 110V: the maximum power is 800W
When the power supply voltage is 220V: the maximum power is 1600W
If you need to control the load exceeding this limit parameter, please install an intermediate relay
7.Alarm Output£º800W-1600W(Resistive load)
8.output method£ºRelay normally open contact
9.working environment£ºTemperature -20~80¡É, relative humidity ¡Â80%
10.Installation method£ºScrew wall mounting
11.Dimensions£º115*90*40
12.Safety standard certification£ºCE
13.Environmental certification£ºCCC
14.Dimensions£ºROHS-2.0